Named in an ADA lawsuit or received a demand letter? Start here or call (866) 274-9774.

Guide · For Attorneys & Owners

How To Read An Accessibility Report

Section by section, with ten signs of a weak report.

This guide is general information, not legal advice. Laws and court decisions change. Consult a licensed attorney.

A report should not simply list problems. It should help the reader understand what matters, why it matters and what to do next. This guide explains how an accessibility report is built, how to read each part, and how to tell a report you can rely on from one you cannot.

1. Start With Three Questions The Report Must Answer

Before reading any finding, look for these. If the report does not answer them, its findings cannot be evaluated.

Which standard was applied, and why? Accessibility requirements depend on when the building was built and altered.

SITUATIONSTANDARD THAT GENERALLY APPLIES
Built for first occupancy after January 26, 1993 and before the 2010 Standards took effect1991 ADA Standards (new construction)
Built or altered on or after March 15, 20122010 ADA Standards
Older building, not alteredBarrier removal where "readily achievable" (28 CFR 36.304), measured against the 2010 Standards
Element that complied with the 1991 Standards and has not been altered since March 15, 2012Safe harbor: need not be modified to the 2010 Standards (28 CFR 36.304(d)(2))
Florida propertiesFlorida Accessibility Code for Building Construction and Florida Statutes s. 553.5041 for parking, which are stricter than federal minimums in places

A report that cites only "the ADA" for every finding, with no dates and no distinction between new construction, alteration and barrier removal, has skipped the analysis that most often decides a case.

What was the scope? Whole property or claim-specific? Common areas, tenant space or both? Which areas were not accessed, and why?

Who measured, when and with what? Date of the site visit, the inspector's name and qualifications, and the instruments used (digital level, tape, door pressure gauge).

2. The Parts Of A Report & How To Read Them

Executive Summary

Read it last, not first. It should state the number of conditions found, how many are high priority, and the recommended next steps. Check that every statement in it is supported by a finding in the body.

Property Description

Use, size, year built, known alterations, number of parking spaces, who controls which areas. The parking count matters: it sets the number of accessible spaces required. The alteration history matters: it sets the applicable standard.

Findings

Each finding should have six parts. If any is missing, ask for it.

PARTWHAT IT SHOULD SAYWHY IT MATTERS
LocationExactly where: "north lot, space nearest entrance"So the condition can be found again
ElementWhat was measured: "access aisle width"Ties the finding to a specific requirement
Measured conditionThe number: "48 inches"An observation without a measurement is an opinion
RequirementThe number and the section: "60 inches minimum, 2010 Standards 502.3.1; Florida: 5 feet, s. 553.5041(5)(c)"Lets the reader verify it
PhotographThe condition with the tape or level visibleThe record that survives after the condition is corrected
RecommendationWhat would correct itTurns a finding into an action

Priority Ranking

Not every condition is equally urgent. A sound report ranks findings. The Department of Justice's order for existing facilities is a sensible backbone (28 CFR 36.304(c)):

  1. Access from public sidewalks, parking and transportation (parking, routes, entrance)
  2. Access to the areas where goods and services are provided
  3. Restrooms
  4. Everything else

Within each, a good report also considers how far the condition departs from the requirement, how visible it is, and how costly it is to correct.

Remediation Commentary

For each significant item: what the correction involves, what else it affects, whether a permit is likely, and whether it is the kind of step the regulations list as an example of readily achievable barrier removal (ramps, curb cuts, widening doors, grab bars, accessible parking and others in 28 CFR 36.304(b)).

Appendices

Photo log, measurement log, site plan with locations marked, the inspector's qualifications, and in a litigation report the allegations reviewed.

3. Reading The Measurements

Slopes. Reports give slopes as ratios or percentages. A digital level reads percent.

RATIOPERCENTWHERE IT IS THE LIMIT
1:48about 2.1%Parking spaces, access aisles, landings, cross slope of routes
1:205%Running slope of a walkway. Steeper than this is a ramp
1:12about 8.3%Ramps and curb ramps
1:1010%Flared sides of curb ramps

Where a slope was taken matters. A space can read 1.5 percent at one corner and 4 percent at another. Look for multiple readings and the direction of each.

Tolerances. The 2010 Standards recognize conventional construction tolerances for dimensions that are not stated as a range. Where the requirement is a range (for example, toilet centerline 16 to 18 inches), the range already includes the tolerance. A report that calls a 17 3/4 inch centerline a violation, or forgives a 19-inch one as "within tolerance", has misapplied this.

Width. Door clear width is measured from the face of the open door to the stop, not from frame to frame. Parking width is measured to the centerline of the stripe.

4. Common Requirements Cited, For Reference

ELEMENT Accessible Route Width2010 STANDARDS BENCHMARK 36 Inches Minimum
Door clear width32 inches minimum
Threshold1/2 inch maximum
Door hardware height34 to 48 inches
Interior door opening force5 pounds maximum
Door closing time (90 to 12 degrees)5 seconds minimum
Pull-side latch clearance18 inches minimum
Toilet centerline from side wall16 to 18 inches
Toilet seat height17 to 19 inches
Grab bar height33 to 36 inches
ELEMENT2010 STANDARDS BENCHMARK
Side grab bar length / rear grab bar length42 inches / 36 inches minimum
Lavatory rim height / knee clearance34 inches maximum / 27 inches minimum
Mirror, bottom of reflecting surface40 inches maximum
Reach range15 to 48 inches
Sales and service counter36 inches high maximum, 36 inches long minimum
Parking sign, bottom edge60 inches minimum
Protruding objects (27 to 80 inches high)4 inches maximum projection

5. Ten Signs Of A Weak Report

  1. No statement of which standard was applied to which element.
  2. No construction or alteration dates.
  3. Findings without measurements ("restroom not compliant").
  4. Measurements without photographs.
  5. Requirements stated without section numbers.
  6. Florida property, federal dimensions only.
  7. Every finding treated as equally serious.
  8. Recommendations of "consult a contractor" with no target dimension.
  9. Conclusions of law ("the defendant violated the ADA") instead of findings of fact.
  10. No statement of what was not inspected.

For attorneys reviewing an opposing report, each of these is a line of inquiry. A rebuttal review tests the other side's findings on exactly these points: standard applied, measurement method, location, and whether the condition still exists.

6. Using The Report

In litigation. Build the allegation table: each paragraph of the complaint against the measured condition, with a status of accurate, partly accurate, unsupported or corrected. This becomes the basis for the answer, for negotiation and, where work is completed, for a mootness motion supported by a declaration.

In negotiation. The priority ranking and correction plan let you propose a specific scope and schedule instead of reacting to the other side's.

In remediation. Give contractors the finding and the target dimension, not the phrase "make it ADA compliant". Re-measure before paying.

After remediation. A Remediation Status Report closes each finding with a date, a measurement and a photograph. In Florida it can also support a certification of conformity or remediation plan filed under s. 553.5141.

In a transaction. Read the executive summary for magnitude, the priority ranking for timing, and the property description for who controls what. Those three drive price, lease allocation and closing conditions.

Questions To Ask Whoever Wrote The Report

  • Which edition of the Standards did you apply to each element, and what dates did you rely on?
  • How many slope readings did you take at each space, and where?
  • Which findings would you correct first, and why?
  • Which findings might fall under the 1991 safe harbor?
  • What did you not inspect?
  • If these corrections were made, what would you need to see to confirm them?

How National ADA-ACN Helps

Litigation Defense Reports, Property Evaluations, Rebuttal and Peer Reviews, and Remediation Status Reports, plus CLE-style sessions on this material for legal teams. We have supported more than 1,500 matters over 15+ years.

Sources

  • 2010 ADA Standards for Accessible Design, including section 104.1.1 on tolerances: ada.gov/law-and-regs/design-standards
  • U.S. Access Board, Guide to the ADA Accessibility Standards: access-board.gov/ada/guides
  • 28 CFR 36.304 (barrier removal, priorities, safe harbor): ecfr.gov
  • Florida Statutes s. 553.5041 and s. 553.5141: flsenate.gov

Guides

Related Guides

Share The Property, The Matter & Your Timeline.

We will tell you what a review would involve.